6-30V Relay Module Specifications:

1: Working voltage: 6-30V support micro USB 5.0V power supply
2: Trigger signal source: high-level trigger (3.0V-24V) The signal ground and the system ground are not in the same ground to improve the anti-interference ability of the system (you can also short-circuit the common ground by yourself)
3: Output capacity: can control equipment within DC 30v 5A or AC 220v5A
4: Quiescent current: 20mA Working current: 50mA
5: Service life: more than 100,000 times; working temperature: -40—85°C; size: 6.2×3.8×1.7cm
6: With optocoupler isolation, enhanced anti-interference ability, industrial-grade circuit board, set parameters forever after power off
memory.
7: Package Includes: 1 x Timer Switch Module
Special attention: The relay output is a passive contact, uncharged output, which controls the on-off function of a line.

Features 6-30V Relay Module Switch:

1. Wide voltage power supply (6~30V) supports micro USB 5.0V power supply, which is very convenient to use;
2. The interface is clear and simple, powerful, easy to understand, and almost meets all your needs;
3. There is a key emergency stop function (STOP key), with reverse connection protection, reverse connection does not burn;
4. Added sleep mode. After enabling, if there is no operation within 5 minutes, the display will be turned off automatically; any key to wake up;
5. Different OP, CL, LOP parameters can be set, these parameters are independent of each other and saved separately;
6. All setting parameters are automatically saved after power-off.

Image of a 6-30V relay module with wiring diagram for delay timer circuit.

How to operate the Relay Module Time Delay Circuit:

P1 mode: After the signal is triggered, the relay is turned on for OP time, and then turned off; in OP time, the following operations
P1.1: The signal is invalid when triggered again
P1.2: The signal triggers again to re-timing
P1.3: The signal triggers the reset again, the relay is disconnected, and the timing stops;
P1.4 Count down the op time, it will be executed once at boot without triggering;
P-2.1: Give the trigger signal, after the relay is turned off for CL time, the relay is turned on for OP time, after the timing is completed, the relay is turned off;
P2.2 P2 function distinguishes trigger re-timing
P3.1: Give the trigger signal, after the relay is turned on for the OP time, the relay will disconnect CL time, and then cycle the above actions, give the signal again in the cycle, the relay will disconnect, and stop timing; the number of cycles (LOP) can be set;
P3.2: There is no need to trigger signal after power-on, the OP time of relay conduction, and CL time of relay disconnection, cycle the above actions; the number of cycles (LOP) can be set;
P-4: Signal holding function. If there is a trigger signal, the timer is cleared and the relay remains on; when the signal disappears, the relay is disconnected after timing the OP; during the timing, there is another signal, and the timer is cleared;

Relay module for 6-30V power supply with trigger and ground connections.

STOP Button Function Expansion:
Relay enable mode:
1. ON: the relay is allowed to conduct during OP conduction;
2. OFF: The relay is forbidden to conduct and is always off;
Short press the STOP button on the main interface to switch between ON and OFF, the current state will flash, and then return to the main interface. (This function is an emergency stop function, one key to open the closed relay)
Sleep mode:
1. C-P sleep mode: within five minutes, without any operation, the digital tube automatically turns off the display, and the program runs normally;
2. O-d normal mode: the digital tube is always on for display;
Long press the STOP button for 2 seconds and then release it to realize the switch between C-P and O-d states. The current state will flash and then return to the main interface.

How to Set Parameters:
1. First determine the working mode of the relay;
2. According to the working mode of the relay, in the main interface (when the module is powered on, it will flash the current working mode (default P1.1 mode), and then enter the main interface,) “Long press the SET button for 2 seconds and then release “Enter the mode selection interface, select the mode to be set by short pressing the UP and DOWN buttons (P1.1~P-4);
3. After selecting the mode to be set (for example, P3.2), short press the SET button to set the corresponding parameters, then the parameters to be set will flash (OP on time, CL off time, LOP cycle times (“– -” represents an infinite cycle)), adjust the parameter value through UP and DOWN, support long press (rapid increase or decrease) and short press (increase or decrease by 1 unit); after setting the parameter value, short press the STOP button To select the position of the decimal point, select the timing range (corresponding time 0.1 second to 999 minutes); short press the SET key to set the next parameter of the current mode, the process is the same as above;
4. After setting the parameters of the selected mode, press and hold the SET button for 2 seconds and then release, the currently set mode will flash, and then return to the main interface. The parameter setting is successful, very simple!
Main interface: “000” (no decimal point) is displayed when the relay is not working, and there is a decimal point when the relay is working, which is very clear!
Mode selection interface: Long press the SET button to enter, after the setting is completed, long press the SET button to exit and return to the main interface.

A final check before payment

Review your options, quantities and the final total before confirming.

Ordering for an occasion

Delivery times are estimates, so leave time before your occasion.

Standard Shipping: Handling (business days) 0–1; Transit (business days) 7–15.

Express Shipping: Handling (business days) 0–1; Transit (business days) 7–15.

View policy
If plans change

Ask the store about your order before making return or refund arrangements.

Please contact us for the refund processing timeframe before returning an item.

View policy
Planning delivery

Review the available services for your destination.

Standard Shipping · United States: $0.00

Express Shipping · United States: $3.99

View policy
Return arrangements

Contact the store first to check the conditions for your item.

United States · Return window (days after delivery): 30. Return method: By mail. Return postage: Seller pays.

View policy

Customer Reviews (4.6 / 5 · 5 reviews)

Mia G. ★★★★★

Set the delay with the trimpot and it cycled my 12V pump perfectly on the first try. Really like that it accepts both 6-30V and USB power, makes bench testing a breeze.

Hannah Q. ★★★★★

I needed a timer that could handle both 12V and 24V systems, and this module works perfectly with my setup for cycling a pump on and off. The micro USB backup power is a nice touch for testing without wiring everything up.

Edward L. ★★★★★

Was a bit worried about the signal ground not being shared, but the high-level trigger works flawlessly with my 12V setup. The micro USB power option is a lifesaver for bench testing.